WIKA PGS21 User Manual

Page 9

Advertising
background image

WIKA operating instructions models PGS10, PGS11 and PGS21

9

4. Design and function / 5. Electrical switch contacts

4. Design and function

Description
Bourdon tube measuring elements are widely used in technical pressure

measurement due to their robustness and ease-of-use. Under the influence

of pressure, these measuring elements deform within their elastic limits.

This motion is converted, via a mechanical movement (toothed gear), into

a rotational motion. To this, an electrical limit switch is connected - the

magnetic snap-action contact. The contact closes or opens the connected

electrical circuits when the settable limit values are exceeded.

Scope of delivery
Cross-check scope of delivery with delivery note.

5. Electrical switch contacts

Electrical connection

■

The electrical connection must only be made by qualified skilled

personnel

■

Connection of the switches via cable or via screw terminals in the

terminal box (L-connector)

■

The terminal assignment is stated on the product label of the pressure

gauge

■

The gauges must be connected to the equipotential bonding of the plant

Electromagnetic compatibility

EMC per EN 60947-5-2.

The instruments are to be protected against strong electromagnetic fields.

11581752.02 09/2013 GB/D/F/E