Specifications – WIKA OLS-C20 User Manual

Page 8

Advertising
background image

8

WIKA operating instructions mini limit switch, model LSO.02

13334591.02 10/2010 GB/D/F/E

GB

3. Specifications

3. Specifications

General Data

Measuring accuracy

±0.5 mm

Ambient light

max. 10,000 Lux (immersed)

Mounting position

any

Weight

0.15 kg

Design Data

Medium temperature

-30 ... +140 °C

Ambient temperature

-25 ... +70 °C

Working pressure

0 ... 5 MPa (0 ... 50 bar)

Measuring length

see drawing on page 9

Process connection

G ½ A, M16 x 1.5, ½ NPT etc. see drawing on page 9

Materials

■

Sensor

■

Tip

■

Electronics housing

Stainless steel 1.4571

Quartz

Stainless steel 1.4301

Electrical Data

Supply voltage

DC 24 V -25 ... +30 %

Supply current max.

40 mA

Power consumption

1 W

Output

■

Voltage

■

Current

■

other

DC 24 V

0.5 A at Tu 70 °C

short-circuit protection, reverse voltage protection,

current, voltage and power limitation

Switching current

(Tu = 70 °C)

0.5 A

Electrical connection

■

PVC cable 3 x 0.14 mm²

■

Plug 4-pole series 713, M12

Ingress protection

■

With plug

■

With cable

IP 65 per EN 60 529

IP 66 per EN 60 529

For further specifications see WIKA data sheet LM 31.01 and order documentation.