WIKA DI10 User Manual

Page 20

Advertising
background image

6 Commissoning, operation

20

WIKA operating instructions digital indicator DI10

Menu level Parameterization level




dot


Setting the decimal point, dot:

0

0.0

0.00

0.000


The decimal point on the display can be moved with [

] [

]

and confirmed with [P]. The display then switches back to the
menu level again.




SEC


Setting the display time, SEC:

0.1

0.9 dann 1.0

10.0


The display time is set with [

] [

]. The display moves up in

increments of 0.1 up to 1 second and in increments of 1.0 to
10.0 seconds. Confirm the selection by pressing the [P]
button. The display then switches back to the menu level
again.





run


Activation / deactivation of the programming lock and
completion of the standard parameterization, run:

ULOC

LOC


With the aid of the [

] [

] keys, you can choose between the

deactivated key lock ULOC (works setting) and the activated
key lock LOC. Make the selection with [P]. After this, the
display confirms the settings with "- - - -", and automatically
switches to operating mode.

If LOC was selected, the keyboard is locked. To get back into
the menu level, you must press [P] for 3 seconds in operating
mode. You must now enter the CODE (works setting 1 2 3 4)
that appears using the [

] [

] keys plus [P] to unlock the

keyboard. FAIL appears if the input is wrong.

Advertising