OPERATION

General

When the operate button (Figure 5) is pressed, power
is supplied to the water pump (MS-150/155/355) or
solenoid (MS-250/255). The pump/solenoid operates
and water sprays onto the heated steam generator.
The water flashes immediately into live steam and
shoots down onto the product.

One of two operational modes can be used: Single
Shot
or Timed Cycle

SINGLE SHOT

The operate button is pressed to initiate a single timed
shot. The control board applies power to the water
pump/solenoid and a timed “shot” of steam occurs.

TIMED CYCLE

The control is set to the desired cook time (up to 99
minutes, 59 seconds), then the Start/Stop Button is
pressed. The main control board applies power to the
water pump/solenoid at regular intervals for the dura-
tion of the displayed cycle time. The display counts
down to zero when the cycle is complete sounding a
audible signal then reverts back to the original pro-
grammed cycle time. The unit is ready for the next
cycle when the green ready light is on.

READY

UP

DOWN

PROGRAM

START/STOP

POWER

Figure 5. Operating Controls

Ready Light

Rocker Switch
(Power On/Off)

Operate
Button

Message
Display

Start/Stop
Button

CAUTION

Water pressure must not exceed 25 psi (1.7
kg/cm

2

or 172 kPa). Higher water pressures may

cause poor performance or flooding. To reduce
water pressure, install a water pressure regulator,
and set water pressure to 20 psi (1.4 kg/cm

2

or 138

kPa). To order a water pressure regulator from
your authorized service center, order Roundup
part no. 7000235.

RE

AD

Y

Figure 4. Connecting Water Supply to MS-250/255

Hi-Limit Reset Button

Water Connect Fitting

Power Cord

Quick Disconnect
Insert

Model MS-250/255

The MS-250/255 requires a direct water hookup. An
installation kit is packed inside the unit.

1. Connect the 1/4" (6.5 mm) I.D. flexible tubing to

your cold water line using the supplied hose
clamp.

2. Push the quick disconnect insert into the fitting on

the back of the unit (Figure 4).

NOTE: Incoming water is controlled by a solenoid
valve inside the electrical housing of the steamer.