2 flyback transformer, 1 electrical specifications – Cirrus Logic CDB1611-8W User Manual

Page 13

Advertising
background image

CDB1611-8W

DS978DB4

13

6.2

Flyback Transformer

The flyback transformer stage is a quasi-resonant peak current-regulated DC-DC converter capable of delivering
the highest possible efficiency with constant current output while minimizing line frequency ripple. The auxiliary wind-
ing is used for zero-current detection and overvoltage protection.

Figure 8. Flyback Transformer Schematic

6.2.1

Electrical Specifications

Characteristics conditions:

• Operating temperature range: -25 °C to +120 °C (including coil heat)

Notes:

9. Time = 2sec.

10. Measured across pins 3 and 4.
11. Measured across pins B and A.
12. Measured across pins 2 and 1.

Parameter

Condition

Symbol

Min

Typ

Max

Unit

Flyback Transformer
Electrical Strength

(Note 9)

f

operate

=50/60Hz

-

4K

-

V

RMS

Primary Inductance

(Note 10)

f

resonant

=10kHz, 0.3V at 20°C

L

P

13.05

14.5

15.95

mH

Primary Leakage Inductance

(Note 10)

f

resonant

=10kHz, 0.3V at 20°C

L

K

-

106

-

H

Primary DC Resistance

(Note 10)

t

DCR

=20°C

5.25

7.0

8.75

Secondary DC Resistance

(Note 11)

t

DCR

=20°C

-

120

-

m

Auxiliary DC Resistance

(Note 12)

t

DCR

=20°C

-

400

-

m

113T

#36 AWG

(0.13 mm)

67 T

# 36AWG

(0.13mm)

10 T

# 36AWG

(0.13mm)

Primary

4

5

3

1

Auxiliary

2

Secondary

10T

#27AWG

(0.35mm)

B

A

Advertising