6.2

Flyback Transformer

The flyback transformer stage is a quasi-resonant current-regulated DC-DC converter capable of delivering the high-
est possible efficiency at a constant current while minimizing line frequency ripple. The auxiliary winding is used for
zero-current detection and overvoltage protection.

6.2.1

Electrical Specifications

Characteristics conditions:

• Operating temperature range: -25 °C to +120 °C (including coil heat)

Notes:

3.

Time = 2 s.

4.

Measured across pins 3 and 4

5.

Measured across pins B and A

6.

Measured across pins 2 and 1

Parameter

Condition

Sym

Min

Typ

Max

Unit

Flyback Transformer
Electrical Strength

(Note 3)

f

operate

=50/60Hz

-

4K

-

V

RMS

Primary Inductance

(Note 4)

f

resonant

=10kHz, 0.3V at 20°C

L

P

2.79

3.1

3.41

mH

Primary Leakage Inductance

(Note 4)

f

resonant

=10kHz, 0.3V at 20°C

L

K

-

-

15

H

Primary DC Resistance

(Note 4)

t

DCR

=20°C

2.175

2.90

3.625

Secondary DC Resistance

(Note 5)

t

DCR

=20°C

-

-

0.22

Auxiliary DC Resistance

(Note 6)

t

DCR

=20°C

0.3975

0.53

0.6625

113T

#36 AWG

(0.13 mm)

67 T

# 36AWG

(0.13mm)

10 T

# 36AWG

(0.13mm)

Primary

4

5

3

1

Auxiliary

2

Secondary

10T

#27AWG

(0.35mm)

B

A

Figure 8. Flyback Transformer Schematic