Transformer construction, 1 flyback transformer, 1 electrical specifications – Cirrus Logic CRD1615-8W User Manual

Page 14

Advertising
background image

CRD1615-8W

14

DS1002RD3

7. TRANSFORMER CONSTRUCTION

The CRD1615-8W provides power factor correction and dimmer compatibility with a constant output current, quasi-
resonant flyback stage. The following sections describe the flyback transformer installed on the CRD1615-8W.

7.1

Flyback Transformer

The flyback transformer stage is a quasi-resonant peak current-regulated DC-DC converter capable of delivering
the highest possible efficiency with constant current output while minimizing line frequency ripple. The auxiliary wind-
ing is used for zero-current detection and overvoltage protection.

7.1.1

Electrical Specifications

Characteristics conditions:

• Operating temperature range: -25 °C to +120 °C (including coil heat)

Notes:

1. Time = 2sec.
2. Measured across pins 4 and 5.
3. Measured across pins B and A.
4. Measured across pins 12 and 7.

Parameter

Condition

Symbol

Min

Typ

Max

Unit

Flyback Transformer
Electrical Strength

(Note 1)

f

operate

=50/60Hz

-

3.75

-

kV

RMS

Primary Inductance

(Note 2)

f

resonant

=10kHz, 0.3V at 20°C

L

P

2.34

2.6

2.86

mH

Primary Leakage Inductance

(Note 2)

f

resonant

=10kHz, 0.3V at 20°C

L

K

-

-

55

H

Primary DC Resistance

(Note 2)

t

DCR

=20°C

4.64

5.8

6.96

Secondary DC Resistance

(Note 3)

t

DCR

=20°C

0.208

0.26

0.312

m

Auxiliary DC Resistance

(Note 4)

t

DCR

=20°C

0.44

0.55

0.66

m

91T

#34 AWG

(0.15 mm)

105T

# 34AWG

(0.15mm)

34T

# 31AWG

(0.23mm)

Primary

4

6

5

12

Auxiliary

7

Secondary

34T

#28AWG

(0.30mm)

A

B

Figure 10. Flyback Transformer Schematic