DS1003RD4
9. CONDUCTED EMI
Device Under Test: CRD1616-8W-Z
Operating Conditions: NOMINAL
Test Specification: EN55022:2010
Operator Name: CAL
Scan Settings (1 Range)
Final Measurement
Detectors: QP, AV
Peaks: 25
Meas Time: See scan settings
Acc. Margin: 12dB
Final Measurement Results
Frequencies
Receiver Settings
Start
Stop
Step
Res BW
M-Time
Atten
Preamp
150kHz
30MHz
4.5kHz
9kHz (6dB)
50ms
Auto
Off
Trace
Frequency
(MHz)
Level
(dB
V)
Limit
(dB
V)
Delta Limit
(dB)
Delta Ref
(dB)
Comment
1 QP
0.15
58.20
66.00
-7.80
N / on
2 AV
0.1815
42.87
54.42
-11.55
N / on
1 QP
2.5125
52.99
56.00
-3.01
N / on
2 AV
10.0005
40.93
50.00
-9.07
N / on
* = Limit Exceeded