14

DS1043RD2

7. TRANSFORMER CONSTRUCTION

The CRD1615A-8W provides power factor correction and dimmer compatibility with a constant output current, quasi-
resonant flyback stage. The following sections describe the flyback transformer installed on the CRD1615A-8W.

7.1

Flyback Transformer

The flyback transformer stage is a quasi-resonant peak current-regulated DC-DC converter capable of delivering
the highest possible efficiency with constant current output while minimizing line frequency ripple. The auxiliary wind-
ing is used for zero-current detection and overvoltage protection.

7.1.1

Electrical Specifications

Characteristics conditions:

• Operating temperature range: -25 °C to +120 °C (including coil heat)

Notes:

1. Time = 2sec.
2. Measured across pins 4 and 5
3. Measured across pins B and A
4. Measured across pins 12 and 7

Parameter

Condition

Symbol

Min

Typ

Max

Unit

Flyback Transformer
Electrical Strength

(Note 1)

f

operate

=50/60Hz

-

3.75

-

kV

RMS

Primary Inductance

(Note 2)

f

resonant

=10kHz, 0.3V at 20°C

L

P

0.8

0.9

1.0

mH

Primary Leakage Inductance(Note 2)

f

resonant

=10kHz, 0.3V at 20°C

L

K

-

-

20

H

Primary DC Resistance

(Note 2)

t

DCR

=20°C

1.9

2.2

2.5

Secondary DC Resistance (Note 3)

t

DCR

=20°C

0.8

1.0

1.2

m

Auxiliary DC Resistance

(Note 4)

t

DCR

=20°C

3.0

3.5

4.0

m

48T

#27 AWG

(0.36 mm)

48 T

# 27AWG

(0.36mm)

48T

# 33AWG

(0.18mm)

Primary

4

6

5

12

Auxiliary

7

Secondary

(Triple Insulated )

48T

#30AWG

(0.255mm)

A

B

Figure 10. Flyback Transformer Schematic