An374 – Cirrus Logic AN374 User Manual

Page 20

Advertising
background image

AN374

20

AN374REV2

Figure 10 shows a method for selecting the correct power train topology.

No

Yes

No

Start

Flyback

Flyback

Buck

Isolation

required?

Required

V

MODEx

/

V

BST

< 10%

Yes

Figure 10. Selecting the Correct Power Train Topology