10. CONDUCTED EMI
Device Under Test: CRD1630-10W
Operating Conditions: NOMINAL at 25
C
Test Specification: EN555022
Operator Name: JC
Scan Settings (1 Range)
Final Measurement
Detectors: PK+, AV
Peaks: 10
Meas Time: See scan settings
Acc. Margin: 3dB
Final Measurement Results
Frequencies
Receiver Settings
Start
Stop
Step
Res BW
M-Time
Atten
Preamp
150kHz
30MHz
4.5kHz
9kHz (6dB)
10ms
Auto
Off
Trace
Frequency
(MHz)
Level
(dB
V)
Limit
(dB
V)
Delta Limit
(dB)
Delta Ref
(dB)
Comment
1 PK+
2.427
53.34
56.00
-2.66
L1 / on
* = Limit Exceeded
1 MHz
10 MHz
150 kHz
30 MHz
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
0.0
100.0
dBμV
Limits
55022MQP
55022MAV
Transducer
ENV216
Traces
PK+
AV
Figure 25. Conducted EMI