modeRateControl:

Must be set the same on both the sending and receiving interfaces. There is one modeRateControl
variable per CobraNet

TM

interface and its value affects all audio channels. All channels on a

particular CobraNet

TM

node must be set to the same latency (1 1/3, 2/23 or 5 1/3) and sample rate

(48-kHz or 96-kHz). Sample sizes (16, 20 or 24 bits), as specified by txSubFormat, can vary by
channel, and are not affected by modeRateControl. The sample rate and latency component of
txSubFormat must set in agreement with the value of modeRateControl.

Default:

0x600 - 5 1/3 mS latency, 48kHz

CobraNet

TM

Audio Routing Primer Rev. 1.2 ©Copyright 2004 Cirrus Logic, Inc