1 test select, Cdb5378 – Cirrus Logic CDB5378 User Manual
Page 48

CDB5378
48
DS639DB4
3.4.1
Test Select
The Test Select control sets the type of analysis to be run on the collected data set.
Control
Description
Time Domain
Runs a min / max calculation on the collected data set and then plots sample data
value vs. sample number.
Histogram
Runs a histogram calculation on the collected data set and then plots sample occur-
rence vs. sample value. Only valid for noise data since sine wave data varies over
too many codes to plot as a histogram.
Signal FFT
Runs an FFT on the collected data set and then plots frequency magnitude vs. fre-
quency. Statistics are calculated using the largest frequency magnitude bin as a full-
scale signal reference.
Noise FFT
Runs an FFT on the collected data set and then plots frequency magnitude vs. fre-
quency. Statistics are calculated using a simulated full-scale signal as a full-scale sig-
nal reference.