6 grounding and power supply decoupling, 7 analog output and filtering, Figure 10. cs4334 data format (i·s) – Cirrus Logic CS4339 User Manual

Page 15: Figure 11. cs4335 data format, Figures 10

Advertising
background image

15

CS4334/5/8/9

down state is related to the value of the DC-blocking capacitance. For example, with a 3.3

F capacitor, the

time that the device must remain in the power-down state will be approximately 0.4 seconds.

4.6

Grounding and Power Supply Decoupling

As with any high resolution converter, the CS4334 family requires careful attention to power supply and
grounding arrangements to optimize performance. Figure

1

shows the recommended power arrangement

with VA connected to a clean +5V supply. For best performance, decoupling capacitors should be located
as close to the device package as possible with the smallest capacitor closest.

4.7

Analog Output and Filtering

The analog filter present in the CS4334 family is a switched-capacitor filter followed by a continuous time
low pass filter. Its response, combined with that of the digital interpolator, is given in

Figures 15

-

22

.

LRCK

SCLK

Left Channel

Right Channel

SDATA

+3 +2 +1 LSB

+5 +4

MSB -1 -2 -3 -4 -5

+3 +2 +1 LSB

+5 +4

MSB -1 -2 -3 -4

Internal SCLK Mode

External SCLK Mode

I²S, 16-Bit data and INT SCLK = 32 Fs if
MCLK/LRCK = 512, 256 or 128
I²S, Up to 24-Bit data and INT SCLK = 48 Fs if
MCLK/LRCK = 384 or 192

I²S, up to 24-Bit Data
Data Valid on Rising Edge of SCLK

Figure 10. CS4334 Data Format (I²S)

LRCK

SCLK

Left Channel

Right Channel

SDATA

+3 +2 +1 LSB

+5 +4

MSB -1 -2 -3 -4 -5

+3 +2 +1 LSB

+5 +4

MSB -1 -2 -3 -4

Internal SCLK Mode

External SCLK Mode

Left Justified, up to 24-Bit Data
INT SCLK = 64 Fs if MCLK/LRCK = 512, 256 or 128
INT SCLK = 48 Fs if MCLK/LRCK = 384 or 192

Left Justified, up to 24-Bit Data
Data Valid on Rising Edge of SCLK

Figure 11. CS4335 Data Format