4. APPLICATIONS

4.1

Sample Rate Range/Operational Mode

The device operates in one of two operational modes determined by the Master Clock to Left/Right Clock ratio (see
section 4.2). Sample rates outside the specified range for each mode are not supported.

4.2

System Clocking

The device requires external generation of the master (MCLK) and left/right (LRCK) clocks. The device also requires
external generation of the serial clock (SCLK) if the internal serial clock is not used. The LRCK, defined also as the
input sample rate Fs, must be synchronously derived from MCLK according to specified ratios. The specified ratios
of MCLK to LRCK, along with several standard audio sample rates and the required MCLK frequency, are illustrated
in Tables 2 and 3.

4.2.1 Internal Serial Clock Mode

The device will enter the Internal Serial Clock Mode if no low to high transitions are detected on the SCLK pin
for 2 consecutive periods of LRCK. In this mode, the SCLK is internally derived and synchronous with MCLK
and LRCK. The SCLK/LRCK ratio is either 32, 48, or 64 depending upon the MCLK/LRCK ratio and the Digital
Interface Format selection (see Table 4).

Input Sample Rate (Fs)

MODE

4 kHz - 50 kHz

Single-Speed Mode

50 kHz - 100 kHz

Double-Speed Mode

Table 1. CS4340 Speed Modes

Sample Rate

(kHz)

MCLK (MHz)

256x

384x

512x

32

8.1920

12.2880

16.3840

44.1

11.2896

16.9344

22.5792

48

12.2880

18.4320

24.5760

Table 2. Single-Speed Mode Standard Frequencies

Sample Rate

(kHz)

MCLK (MHz)

128x

192x

64

8.1920

12.2880

88.2

11.2896

16.9344

96

12.2880

18.4320

Table 3. Double-Speed Mode Standard Frequencies