CS4341

4

DS298F5

1.

CHARACTERISTICS AND SPECIFICATIONS

(Min/Max performance characteristics and specifications are guaranteed over the Specified Operating Conditions.
Typical performance characteristics are derived from measurements taken at T

A

= 25

°C.)

SPECIFIED OPERATING CONDITIONS

(All voltages with respect to AGND = 0 V.)

ABSOLUTE MAXIMUM RATINGS

(AGND = 0 V; all voltages with respect to AGND. Operation beyond

these limits may result in permanent damage to the device. Normal operation is not guaranteed at these extremes.)

Notes: 1. Any pin except supplies.

Parameters

Symbol

Min Nom

Max

Units

DC Power Supply

Nominal 3.3 V
Nominal 5.0 V

VA
VA

2.7

4.75

3.3
5.0

3.6
5.5

V
V

Specified Operating Temperature

-KS/CZZ

(Power Applied)

T

A

-10

-

+70

°C

Parameters

Symbol

Min

Max

Units

DC Power Supply

VA

-0.3

6.0

V

Input Current

(Note 1)

I

in

-

±10

mA

Digital Input Voltage

V

IND

-0.3

VA+0.4

V

Ambient Operating Temperature (power applied)

T

A

-55

125

°C

Storage Temperature

T

stg

-65

150

°C