Table 2. cdb4352 jumper settings, Design note, 1 cdb4352 revision a.0 – Cirrus Logic CDB435 User Manual

Page 11: 2 cdb4352 revision b.0, Cdb4352

Advertising
background image

DS684DB1

11

CDB4352

Table 2. CDB4352 Jumper Settings

*Default Factory Settings.

10.DESIGN NOTE

10.1

CDB4352 Revision A.0

D2 has been removed and shorted and R2 has been removed.

The serial audio decode table for S1 is incorrect. ‘01’ should be RJ-24 and ‘10’ should be LJ

The polarity of the silkscreen for Z1, Z2, Z3, Z4, and Z5 is incorrect

The CS4352 revision is A1

10.2

CDB4352 Revision B.0

No errors at this time

JUMPER /

SWITCH

PURPOSE

POSITION

FUNCTION SELECTED

J7

Selects source of voltage for

the +5V supplies

+5 V

*+5V_REG

Voltage source is +5 V test point (TP8)

Voltage source is +5 V regulator

J4

Selects source of voltage for

the VD supplies

VD

*+3.3V REG

Voltage source is VD test point (TP2)

Voltage source is +3.3 V regulator

J5

Selects source of voltage for

the VL supply

VL

*+3.3V REG

Voltage source is VL binding post

Voltage source is +3.3 V regulator

J6

Selects source of voltage for

the VA supply

VA

*+3.3V REG

Voltage source is VA test point (TP7)

Voltage source is +3.3 V regulator

J8

Current measure for VD

*shunted

When shunt is removed, the voltage can be measured

across a fixed resistance to determine current.

J9

Current measure for VL

*shunted

When shunt is removed, the voltage can be measured

across a fixed resistance to determine current.

J10

Current measure for VA

*shunted

When shunt is removed, the voltage can be measured

across a fixed resistance to determine current.

J11

Current measure for VA_H

*shunted

When shunt is removed, the voltage can be measured

across a fixed resistance to determine current.

S1

Sets clock source, CS8416

clock speed, and CS4352 set-

tings

*1 = open

*2, 3, 4, 5 = closed

position 1: 0 = external clock source, 1 = CS8416

position 2: 0 = 8416 MCLK is 256xFs, 1 = 128xFs

Position 3,4,5: see CS4352 datasheet

S2

Reset

-

Enables reset for CS4352 and CS8416 when pressed

J12
J17

Mute Disable

*LED

MUTE

Bypasses muting to turn on LED

Normal muting circuit

Advertising