8. ERRATA

CDB4360 Revision A.0

The CDB4360 revision A.0 has the following erra-
ta. The silkscreen for J18 is reversed. The right po-
sition should be labeled “CP” and the left position

should be labeled “SA”. The labeling is correct in
the schematics.

CDB4360 Revision B.0

The CDB4360 revision B.0 has no Errata.

CONNECTOR

INPUT/OUTPUT

SIGNAL PRESENT

+5 V

Input

+ 5 Volt power

VA, VD

Input

+ 3.0 Volt to + 5.0 Volt power for the CS4360

VLC, VLS

Input

+1.8 Volt to +5.0 Volt power for the Level Shifters and the CS4360

GND

Input

Ground connection from power supply

Coax Input

Input

Digital audio interface input via coax

Optical Input

Input

Digital audio interface input via optical

J24

Input/Output

I/O for master, serial, left/right clocks and serial data

Parallel Port

Input/Output

Serial connection to PC for SPI and Two Wire mode control port
signals

J17

Input/Output

I/O for SPI and Two Wire mode control port signals

AOUTAx, AOUTBx

Output

Line outputs

Table 1. System Connections

JUMPER/

SWITCH

PURPOSE

POSITION

FUNCTION SELECTED

S1 (DIP SW)

Enable/Disable the
CS8414

*CLOSED

OPEN

CS8414 is enabled (J24 is an output)
Disabled (External Clocks and Data are input via
J24)

Reset (S2)

Resets the CDB4360

J18

Selects Stand-Alone or
Control Port mode

CP

*SA

Control Port Mode selected
Stand-Alone mode selected

J19, J20

Interface Format

J19

LO

*LO

HI
HI
HI

J20

LO
*HI
LO

HI
HI

Stand-Alone Mode, Left Justified format
Stand-Alone Mode, I2S format
Stand-Alone Mode, Right Justified, 16-bit format
Stand-Alone Mode, Right Justified, 24-bit format
Control Port Mode setting

J22, J21

Mode Select

J22

*LO

LO

HI
HI
HI

J21

*LO

HI

LO

HI
HI

Stand-Alone Mode, Single Speed, no De-Emphasis
Stand-Alone Mode, Single Speed, De-Emphasis
Stand-Alone Mode, Double Speed
Stand-Alone Mode, Quad Speed
Control Port Mode setting

Notes: *Default factory settings

†See Errata section

Table 2. CDB4360 Jumper and Switch settings

Advertising