errata, Errata, Cdb4364 – Cirrus Logic CDB4364 User Manual
Page 5

DS619DB1
5
CDB4364
Table 2. CDB4364 Jumper Settings
*Default Factory Settings.
8. ERRATA
CDB4364 rev C:
-None at this time.
JUMPER /
SWITCH
PURPOSE
POSITION
FUNCTION SELECTED
J15
Selects source of control
data
*shunts on Left
shunts removed
*Control from PC and on-board microcontroller
External control input using center and right columns
J16
JTAG micro programming
-
Reserved for factory use only
S2
Resets CS8416 and
CS4364
The CS8416 must be reset if switch S1 is changed
S1
CS4364 mode settings M0-
M4
1-5
Default: M0, M4 open (HI)
M1, M2, M3 closed (LO)
Sets clock source
6
Sets clock source for CS4364
*open = RX(CS8416), closed = EXT(J11)
Sets MCLK ratio of CS8416
7
Selects 128x (open) or 256x (*closed) MCLK/LRCK
ratio output for CS8416
Selects PCM or DSD mode
8
For PCM input set to *Open, for DSD set to Closed