1. CHARACTERISTICS AND SPECIFICATIONS

1.1 Recommended Operating Conditions

1.2 Electrical Characteristics

NOTES:

1.

Measured at VAC = 240 V and T

A

= 25º C.

2.

Measured at T

A

= 25º C and PF=1.

WARNING

High Voltage Hazard

When the CRD5463PM is connected to AC lines, high voltage is present inside the box.

DO NOT REMOVE THE PROTECTIVE COVER FROM THE CRD5463PM WHEN POWER IS CONNECTED.

Figure 1. Calibration and Test Connection Diagram

NOTES:

1.

Voltage drop and power loss in the cable connecting the CRD5463PM and the reference meter may introduce

additional error.

2.

The measurement bandwidth of the CS5463 is 2 kHz. At low power factor, the CRD5463PM may measure lower

current and higher power factor than the reference meter if the reference meter has a measurement bandwidth
greater than 2 kHz.

3.

When testing at low power factor, the peak load current shall never exceed 22 A.

Parameter

Symbol

Min

Typ

Max

Unit

Voltage Range

V

AC

90

-

260

V

Current Range

RMS Current

I

rms

-

-

15

A

Peak Current

I

peak

-

-

22

A

Frequency Range

Freq

5

2000

Hz

Operating Tempereture

T

A

-40

-

+85

ºC

Parameter

Symbol

Min

Typ

Max

Unit

Power Consumption

(Note 1)

Current Consumption

Power Consumption

I

AC

-

79

-

mA

P

AC

-

2.3

-

W

Accuracy

(Note 2)

RMS Voltage Measurement (90 ~ 260 VAC)

RMS Current Measurement (30 mA ~ 15 A)

Active Power Measurement (3 W ~ 3900 W)

V

accu

-

±0.1

-

%

I

accu

-

±0.2

-

%

P

accu

-

±0.2

-

%

Measurement Bandwidth

BW

-

-

2

kHz

CRD5463PM

AC

SOURCE

AC

Load

GUI

USB

Reference

Meter
(V, A)