An366 – Cirrus Logic AN366 User Manual
Page 22

AN366
22
AN366REV2
RESTORE GAIN CONFIGURATION
(See Figure 15.)
Gain Channel 1, Volt.
SDI = 0x90
0x63 0x401BE3
Write Register V1 Gain
SDO = 0xFF
0xFF 0xFFFFFF
(Page 16, Register 35)
SDI = 0x90
0x23 0xFFFFFF
Read Register V1 Gain
SDO = 0xFF
0xFF 0x401BE3
(Page 16, Register 35)
Gain Channel 1, Curr.
SDI = 0x90
0x61 0x3C4420
Write Register I1 Gain
SDO = 0xFF
0xFF 0xFFFFFF
(Page 16, Register 33)
SDI = 0x90
0x21 0xFFFFFF
Read Register I1 Gain
SDO = 0xFF
0xFF 0x3C4420
(Page 16, Register 33)
Gain Channel 2, Volt.
SDI = 0x90
0x6A 0x4037B6
Write Register V2 Gain
SDO= 0xFF
0xFF 0xFFFFFF
(Page 16, Register 42)
SDI= 0x90
0x2A 0xFFFFFF
Read Register V2 Gain
SDO= 0xFF
0xFF 0x4037B6
(Page 16, Register 42)
Gain Channel 2, Curr.
SDI = 0x90
0x68 0x3C465F
Write Register I2 Gain
SDO = 0xFF
0xFF 0xFFFFFF
(Page 16, Register 40)
SDI = 0x90
0x28 0xFFFFFF
Read Register I2 Gain
SDO= 0xFF
0xFF 0x3C465F
(Page 16, Register 40)
Figure 15. Calibration Window
From NVM
RESTORE
GAIN
CONFIGURATION
6
5
4
3