Switching characteristics (continued), Cs5566, Switching characteristics – Cirrus Logic CS5566 User Manual
Page 8

CS5566
8
DS806PP2
5/4/09
SWITCHING CHARACTERISTICS
(CONTINUED)
T
A
= -40 to +85 °C; V1+ = V2+ = +2.5 V, ±5%; V1- = V2- = -2.5 V, ±5%;
VL - VLR = 3.3 V, ±5%, 2.5 V, ±5%, or 1.8 V, ±5%
Input levels: Logic 0 = 0V Low; Logic 1 = VD+ = High; CL = 15 pF.
13.
SDO and SCLK will be high impedance when CS is high. In some systems SCLK and SDO may require pull-down
resistors.
14.
SCLK = MCLK/2.
Parameter
Symbol Min
Typ
Max
Unit
Serial Port Timing in SSC Mode (SMODE = VL)
Data hold time after SCLK rising
t
7
-
10
-
ns
Serial Clock (Out)
Pulse Width (low)
(Note 13, 14)
Pulse Width (high)
t
8
t
9
100
100
-
-
-
-
ns
ns
RDY rising after last SCLK rising
t
10
-
8
-
MCLKs
CS falling to MSB stable
t
11
-
10
-
ns
First SCLK rising after CS falling
t
12
-
8
-
MCLKs
CS hold time (low) after SCLK rising
t
13
10
-
-
ns
SCLK, SDO tri-state after CS rising
t
14
-
5
-
ns
MCLK
RDY
SCLK(o)
SDO
CS
t
12
t
8
t
13
t
9
t
7
t
11
MSB
MSB–1
LSB
LSB+1
t
14
t
10
Figure 3. SSC Mode - Read Timing, CS falling after RDY falls (Not to Scale)