Cirrus Logic CDB61584A User Manual

Dual line interface unit, Features, Description

Advertising
background image

Copyright

Cirrus Logic, Inc. 1998

(All Rights Reserved)

CDB61584A

Product Databook

Dual Line

Interface Unit

FEATURES

■

Socketed CS61584A Dual Line Interface

■

All Required Components for CS61584A
Evaluation

■

Locations to Evaluate Protection Circuitry

■

LED Status Indications for Alarm Conditions

■

Support for Hardware and Host Modes

DESCRIPTION

The evaluation board includes a socketed CS61584A
dual line interface device and all support components
necessary for evaluation. The board is powered by an
external +5 Volt supply.

The board may be configured for 100

Ω

twisted-pair T1,

75

Ω

coax E1, or 120

Ω

twisted-pair E1 operation. Bind-

ing posts and bantam jacks are provided for line
interface connections. Several BNC connectors provide
clock and data I/O at the system interface. Reference
timing may be derived from a quartz crystal, crystal os-
cillator, or an external reference clock. Four LED
indicators monitor device alarm conditions.

ORDERING INFORMATION:

CDB61584A

Oscillator

Circuit

TTIP1

TRING1

RTIP1

RRING1

TTIP2

TRING2

RTIP2

RRING2

CHANNEL 1

CHANNEL 2

5V+ 0V

TCLK1

TPOS1

(TDATA1)

TNEG1

RCLK1

RPOS1

(RDATA1)

RNEG1

(BPV1)

CHANNEL 1

RESET

CIRCUIT

V+

TCLK2

TPOS2

(TDATA2)

TNEG2

RCLK2

RPOS2

(RDATA2)

RNEG2

(BPV2)

CHANNEL 2

Hardware Control

and Mode Circuit

LED Status

Indicators

Serial Interface

Control Circuit

CS61584A

XTL

REFCLK

DS261DB2 MAR ‘98