Table 6. effect of shorting the listed pin pairs, Table 7. tx_clk mode select, Led indicators – Cirrus Logic CS8952 User Manual

Page 4: Cdb8952

Advertising
background image

4

DS206DB2

CDB8952

Crystal LAN™ 10Base-T and 100Base-X Transceiver

CIRRUS LOGIC ADVANCED PRODUCT DATABOOK

NOTE: When TX_CLK is an input, a shorting cap must

installed on HDR42 to supply TX_CLK to the
CS8952 (see HDR42).

LED Indicators

LED1 - Transmitter Active Indicator.

LED2 - Receiver Active Indicator.

LED3 - Link OK Indicator.

LED4 - Full Duplex Indicator.

LED5 - Collision Indicator.

Pins

Function

Description

1-2

Low Power Start

The CS8952 will enter a low power mode following reset. Only the circuitry
necessary to maintain media impedance and the MII Serial Management
Interface will be operational. The CS8952 checks the status of these pins only
during power-on or reset. A reset or power cycle is required before any changes
in this jumper setting will take effect.

3-4

MII Receive Enable

MII signals RXD[3:0], RX_CLK, RX_DV, and RX_ER are tristated.

5-6

Power Down

The CS8952 is forced into a low power mode. Only the circuitry necessary to
maintain media impedance will be operational.

7-8

CRS Mode Control

The CRS pin will be asserted for receive activity only. The CS8952 checks the
status of these pins only during power-on or reset. A reset or power cycle is
required before any changes in this jumper setting will take effect.

9-10

Bypass Scrambler

The scrambler and descrambler are bypassed, and NRZI FX mode is enabled.
The CS8952 checks the status of these pins only during power-on or reset. A
reset or power cycle is required before any changes in this jumper setting will
take effect.

11-12 Bypass 4B/5B Coders

The 4B5B encoder and decoder are bypassed and 5-bit code groups are used.
RX_ER is used as the fifth receive bit, and TX_ER as the fifth transmit bit. The
CS8952 checks the status of these pins only during power-on or reset. A reset or
power cycle is required before any changes in this jumper setting will take effect.

13-14 Bypass Symbol

Alignment

4B5B coders, scramblers, and NRZI coders are all bypassed, and the CS8952
will make no attempt to identify code-group boundaries. Data on RXD[4:0] and
TXD[4:0] may contain bits from two code groups. The CS8952 checks the status
of these pins only during power-on or reset. A reset or power cycle is required
before any changes in this jumper setting will take effect.

15-16 Loopback

The CS8952 will be placed in loopback mode. When operating in 100 Mb/s
mode, the loopback will be inside the PMD block, and scrambled NRZI data will
be routed directly to the NRZI input port on the descrambler. When in 10 Mb/s
mode, the CS8952 will perform a local ENDEC loopback.

17-18 MII Isolate

The CS8952 will exit from reset with all MII signals tristated except MDIO and
MDC. The CS8952 checks the status of these pins only during power-on or reset.
A reset or power cycle is required before any changes in this jumper setting will
take effect.

19-20 10BASE-T Serial Mode If the CS8952 is in 10 Mb/s mode, data is transferred serially on RXD0 and

TXD0, and the full MII interface is disabled. When the CS8952 is in 100Mb/s
mode, shorting these pins has no effect. The CS8952 checks the status of these
pins only during power-on or reset. A reset or power cycle is required before any
changes in this jumper setting will take effect.

Table 6. Effect of shorting the listed pin pairs

HDR43

TX_CLK pin

CLK25 pin

pins 1-2 shorted

input

25 MHz clock

open

input

not used

pins 2-3 shorted

output

not used

Table 7. TX_CLK Mode Select

Advertising