An372, Figure 4a. fet drain voltage, Figure 4b. current through fet q4 and diode d3 – Cirrus Logic AN372 User Manual
Page 9
Advertising

AN372
AN372REV1
9
The buck stage is supplied by the boost output voltage. The boost output voltage is regulated within 10% by
the boost stage. The buck control loop regulates the output current as long as the peak current has sufficient
margin to rise 10% at the lowest boost output voltage. Figure 4a and Figure 4b show idealized waveforms of
the FET Q4 drain voltage and drain current and the diode D3 current.
Area = N
ު V
OUT
ު T2
Area = V
OUT
ު T2
Area = (V
BST
- V
OUT
)
ު T1
V
BST
V
ZERO
N
ު V
OUT
V
OUT
t
V
Reflected
Figure 4a. FET Drain Voltage
T1
TT
T3
'
C
1-
'
C
T2
1
I
PK(FB)
t
(N+1)
ު I
PK(FB)
I1
I2
Figure 4b. Current Through FET Q4 and Diode D3