III. Front Panel Indicators

indicator

color

function

PTT

red

PTT on

MON

green

Monitor on

F1

yellow

F1/BCD0 output on (open collector low)

F2

yellow

F2/BCD1 output on (open collector low)

F3

yellow

F3/BCD2 output on (open collector low)

F4

yellow

F4/BCD3 output on (open collector low)

F5

yellow

F5/BCD4 output on (open collector low)

IV. Front Panel Adjustments

adjustment

trimpot

location

function

RX AUD

R105

front panel

adjusts radio RX audio output level to remotes

TX MOD

R106

front panel

adjusts remote audio level to radio TX modulation
input *

MIC AUD

R107

front panel

adjusts local mic level to remotes

LINE AUD

R108

front panel

adjusts remote line audio level for all termination
panel functions *

BALANCE

R104

circuit board

sets hybrid balance of remote line

* adjustment is affected by JP2 setting

V. Option Settings

Options are selected by setting jumpers. Pin 1 of each jumper group is toward the left side or the back of the board, depending upon its orientation
in the layout. The following descriptions show the position of each jumper on the board when the board is positioned with the front to the bottom
of the illustration.

JP1 2-Wire / 4-Wire Select

Selects remote line interface

1-2

(default) selects 2-wire interface

2-3

selects 4-wire interface

JP2 Line Audio Gain Mode

Selects Manual or Automatic Line Audio Gain

1-2

(default) selects automatic gain control

2-3

selects manual gain control -- use Line Aud (R108) to adjust.

JP3 Mod Out Source Impedance

Selects low or high Mod Out impedance

1-2

(default) selects low impedance (nominal 600 Ohms)

2-3

selects high impedance (47K Ohms)

JP4 Local Mic Audio Gain

Selects gain of the Local Mic amplifier

1-2

(default) selects low gain

2-3

selects high gain

Advertising