- 14 -

Hard Disk Error

Alarm on hard disk error

Linkage Alarm:

Popup Video Window

Tick for popping up windows on alarm

Electron Map Alarm

Tick for flashing on electron map on alarm

Linkage Record

Tick for recording to local disk on alarm

Sound Alarm

Tick for displaying sound on alarm

Alarm Duration Time

Alarm duration time, default is

10 seconds, selecting range is 5-60
seconds.

Pre-recorded alarm Length

Pre-recording’s length on

alarm, default is 5 seconds, selecting range
is 1-15 seconds.

Arm and Disarm

Arm

Press “Preview”, select area or device for arming,

after arming it will display

logo in front of device

IP or name.

Disarm

After disarm, logo

disappears.

Note: 1. Linkage alarm only is available on arm condition, if device disarms,

linkage alarm is not available.

2. If new alarm happens on alarm, the alarming time should extend.
3. Motion detection and input alarm can linkage popup video window;

electron map alarm, linkage record and sound alarm, others only support
sound alarm.




2.6.3. Manually Record

Select monitoring windows, click

button or right click on windows to

select to record, for recording time and path, referring to schedule record.
Record priority:
1. If enable schedule record and alarm record at the same time, it triggers alarm

in schedule alarm, system should stop schedule alarm and runs alarm linkage
record.

2. If enable schedule record and alarm record at the same time, then enable

manually recording when alarm linkage record happens, system should stop
schedule record and alarm record, and run manually recording.