Hard Disk Error

】

Alarm on hard disk error

Linkage Alarm:

【

Popup Video Window

】

Tick for popping up windows on alarm

【

Electron Map Alarm

】

Tick for flashing on electron map on alarm

【

Linkage Record

】

Tick for recording to local disk on alarm

【

Sound Alarm

】

Tick for displaying sound on alarm

【

Alarm Duration Time

】

Alarm duration time, default is

10 seconds, selecting range is 5-60
seconds.

【

Pre-recorded alarm Length

】

Pre-recording’s length on

alarm, default is 5 seconds, selecting range
is 1-15 seconds.

Arm and Disarm

【

Arm

】

Press “Preview”, select area or device for arming,

after arming it will display

logo in front of device

IP or name.

【

Disarm

】

After disarm, logo

disappears.

Note: 1. Linkage alarm only is available on arm condition, if device disarms,

linkage alarm is not available.

2. If new alarm happens on alarm, the alarming time should extend.
3. Motion detection and input alarm can linkage popup video window;

electron map alarm, linkage record and sound alarm, others only support
sound alarm.




2.6.3. Manually Record

Select monitoring windows, click

button or right click on windows to

select to record, for recording time and path, referring to schedule record.
Record priority:
1. If enable schedule record and alarm record at the same time, it triggers alarm

in schedule alarm, system should stop schedule alarm and runs alarm linkage
record.

2. If enable schedule record and alarm record at the same time, then enable

manually recording when alarm linkage record happens, system should stop
schedule record and alarm record, and run manually recording.