IDS INDUSTRIAL DISPENSER

INSTRUCTIONS

IN-IDS-08

7

OPEN

1

2

4

12

8

11
10

9

'RED' Jumper
Dispense control

switchboard

Dispense
Switches

640 320 160 80 40 20 10

OFF

SPEED[RPM]

OFF

FL

U

ID METERIN

G

IN

C.

P

C

B 300554

P

/N 200293

2

7 6 5 4 3 2 1

#200293

11 10 9

JP

3

JP1

S

W1

The switches are set up as a binary system. This means that multiple switches will add their values to-
gether. For example, to set the motor to run at 500 rpm you must turn on switch 6, 5 and 2 (320+160+20
= 500 rpm). The switches can give a maximum speed of 1000rpm.

The controller will run at a constant pre-set speed via switches 1 through 7, until control current to P1 Pin
9 (VIOLET). is removed. When the current is removed the unit returns to “one cycle per start signal”. At
the first cycle of the dispense mode the pump will “home” itself to the proper starting point. All following
dispense cycles will then home to the proper start position.

Fig 2B

5.0 Speed switches –Switchboard # 200293
The SPEED switches 1 -7 are used for changing the speed settings.