Calibration reference charts maintenance – FMI CTS Series User Manual

Page 4

Advertising
background image








































Page 4 of 9

Calibration Reference Charts

Maintenance


Periodic:

ƒ Rinse the piston where it enters the seal using the small squirt bottle provided. Simply use water. This will help

to eliminate any build up of crystals that may damage seals. Perform this procedure once a day, week, or
whenever you are in the pump house.

ƒ Check for leaks, drips, .. etc. Wipe clean as necessary.

Scheduled: 4 months or 1000 hrs.

ƒ Check for leaks at all fittings and pump head. Change seals and/or fittings if necessary.

ƒ Grease piston drive pins using supplied syringe. Apply a small glob of grease to the piston drive pin where it

enters the drive bearing.

ƒ Wipe box and components down with a cloth, spraying a light mist of protectant oil, such as Silikroil, on all metal

components to help inhibit corrosion.

Extended Shut Down or Storage:

Always flush your CTS unit with fresh water for 10 minutes prior to any extended shut down to ensure easy startup
later. Pump units that are not flushed prior to extended shut down will probably seize and need to be returned to
FMI for rebuild.

IN-CTS-13

1/4/13 HW

Advertising