25

MS-7680

oC Genie Button operation

this field is used to enable/ disable oC Genie function.
drAM Frequency

this is used to adjust the memory frequency.
Adjusted drAM Frequency

it shows the adjusted drAM frequency. read-only.
drAM timing Mode

Select whether drAM timing is controlled by the SPd (Serial Presence detect)

eeProM on the drAM module. Setting to [Auto] enables drAM timings and the

following “Advanced drAM Configuration” sub-menu to be determined by BioS

based on the configurations on the SPd. Selecting [Link or Unlink] allows users to

configure the drAM timings and the following related “Advanced drAM Configu-

ration” sub-menu manually.
Advanced drAM Configuration

Press <enter> to enter the sub-menu. in this sub-menu you can adjust the ad-

vanced drAM timing.

Command rate

this setting controls the drAM command rate.
tCL

this controls the CAS latency, which determines the timing delay (in clock

cycles) before SdrAM starts a read command after receiving it.
trCd

When drAM is refreshed, both rows and columns are addressed separately.

this setup item allows you to determine the timing of the transition from rAS

(row address strobe) to CAS (column address strobe). the less the clock cy-

cles, the faster the drAM performance.
trP

this setting controls the number of cycles for row Address Strobe (rAS) to be

allowed to precharge. if insufficient time is allowed for the rAS to accumulate

its charge before drAM refresh, refreshing may be incomplete and drAM may

fail to retain data. this item applies only when synchronous drAM is installed

in the system.
trAS

this setting determines the time rAS takes to read from and write to memory

cell.
trFC

this setting determines the time rFC takes to read from and write to a memory

cell.
tWr

Minimum time interval between end of write data burst and the start of a pre-

charge command. Allows sense amplifiers to restore data to cells.