MSI H61M-P20 (G3) User Manual

Page 26

Advertising
background image

26

trAS

this setting determines the time rAS takes to read from and write to memory

cell.
trFC

this setting determines the time rFC takes to read from and write to a memory

cell.
tWr

Minimum time interval between end of write data burst and the start of a pre-

charge command. Allows sense amplifiers to restore data to cells.
tWtr

Minimum time interval between the end of write data burst and the start of a

column-read command. it allows i/o gating to overdrive sense amplifiers before

read command starts.
trrd

Specifies the active-to-active delay of different banks.
trtP

time interval between a read and a precharge command.
tFAW

this item is used to set the tFAW (four activate window delay) timing.
tWCL

this item is used to set the tWCL (Write CAS Latency) timing.
Advanced Channel / 2 timing Configuration

Press <enter> to enter the sub-menu. And you can set the advanced memory

timing for each channel.

Gt overClocking

this item allows you to enable/ disable the overclocking of integrated graphics.
Gt ratio

this setting controls the ratio of integrated graphics frequency to enable the inte-

grated graphics to run at different frequency combinations.
Adjusted Gt Frequency

it shows the adjusted integrated graphics frequency. read-only.
Spread Spectrum

When the mainboard’s clock generator pulses, the extreme values (spikes) of the

pulses create eMi (electromagnetic interference). the Spread Spectrum function

reduces the eMi generated by modulating the pulses so that the spikes of the

pulses are reduced to flatter curves.

iMPortANt

if you do not have any eMi problem, leave the setting at [disabled] for optimal

system stability and performance. But if you are plagued by eMi, select the

value of Spread Spectrum for eMi reduction.

*

Advertising
This manual is related to the following products: