Appendix b, Appendix b degraded raid array – MSI X58A-GD45 User Manual

Page 88

Advertising
background image

B-12

Intel RAID

MS-7522

Appendix B

Intel RAID

MS-7522

Appendix B

Degraded RAID Array

A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard drive

members fails or is temporarily disconnected, and data mirroring is lost. As a result, the

system can only utilize the remaining functional hard drive member. To re-establish

data mirroring and restore data redundancy, refer to the procedure below that corre-

sponds to the current situation.

Missing Hard Drive Member

Make sure the system is powered off.
Reconnect the hard drive.
Reboot the system to Windows; the rebuild will occur automatically.

Failed Hard Drive Member

Make sure the system is powered off.
Replace the failed hard drive with a new one that is of equal or greater capacity.
Reboot the system to Intel RAID Option ROM by press <Ctrl> and <I> keys simul-

taneously during the Power-On Self Test (POST).

1.
2.
3.

1.
2.
3.

Select the port of the destination disk for rebuilding, and then press ENTER.

4.