Appendix c, Important – MSI X58A-GD45 User Manual

Page 97

Advertising
background image

Marvell RAID

MS-7522

Appendix C

C-7

Marvell RAID

MS-7522

Appendix C

Rebuilding Virtual Disk

This topic describes the procedure to manually rebuild a degraded virtual disk by using

the Marvell BIOS setup utility. This is applicable to the RAID 1 virtual disk.

Important

The rebuild process is both initiated and completed in the Marvell BIOS setup. The Mar-

vell RAID Utility (MRU), which runs in as OS environment, cannot be used to either initi-

ate, resume, or complete the rebuild process Spare physical disks are not supported.

When a virtual disk is degraded, the “Status” of a virtual disk is changed from Func-

tional to Degrade.
Replace the faulty physical disk with an identical physical disk. (Note: If an identi-

cal disk is unavailable, use a replacement physical disk of larger size or one with

a slightly smaller size as determined the Gigabyte Rounding setting for the virtual

disk.) The BIOS detects the new physical disk and lists the device under “Free

Physical Disks” in the [Topology] pane.
In the [Topology] pane, scroll to “Virtual Disk” (VD 0: XXXX), and press Enter to

select. A menu pops-up as shown below. Scroll to “Rebuild” and press Enter to

configure the rebuild process.

1.

2.

3.

Marvell BIOS Setup (c) xxxx Marvell Technology Group Ltd.

Topology

Information

ID

Namd

Status

Stripe Size

RAID Mode

Size

BGA Status

Number of PDs

Members

: 0

: MRAID1

:

Degrade

: 64K

: RAID1

: 953344MB

: N/A

: 2

: 0 8

HBA 0: Marvell 0

Virtual Disks

VD 0: MRAID1

PD 8: ST3750330MS

Free Physical Disks

PD 0: ST3750XXX

[Delete]
[Rebuild]

Scroll through the list of free disks, and press Space to select a replacement physi-

cal disk. Press Enter to continue.
Press Y to confirm the request when prompted Do you want to rebuild with selected

physical disk on this vd?.
The status of the rebuild process is reflected in the properties of the virtual disk.

4.

5.

6.

Advertising