MS-9638 Server Board

2-12

Fan Power Connectors: CPUFAN 1/2, SYSFAN 1/2/3/4/5/6

The fan power connectors support system cooling fan with +12V. W hen connecting
the wire to the connectors, always take note that the red wire is the positive and
should be connected to the +12V, the black wire is Ground and should be connected
to GND. If the mainboard has a System Hardware Monitor chipset onboard, you must
use a specially designed fan with speed sensor to take advantage of the CPU fan
control.

Important

Please refer to the recommended CPU fans at Intel

®

official website or consult

the vendors for proper CPU cooling fan.

SYSFAN 2/3/4/5/6

SE NS OR

+1 2V

GND

CPUFAN1/2

S

E

N

S

O

R

+

1

2

V

G

N

D

C

O

N

T

R

O

L

SYSFAN1

SE NS OR

+1 2V

GND

Chassis Intrusion Switch Connector: JCI1

This connector connects to a 2-pin chassis switch. If the chassis is opened, the
switch will be short. The system will record this status and show a warning mes-
sage on the screen. To clear the warning, you must enter the BIOS utility and clear the
record.

JCI1

1
2

CINTRU

GND

9638v1.0-2.p65