Seiwa Si-Tex Vector 3D GPS User Manual

Page 35

Advertising
background image

38

35

Appendix A: Troubleshooting

Table A-1 provides troubleshooting for common problems.

Table A-1: Troubleshooting

Symptom

Possible Solution

Receiver fails to power

•

Verify polarity of power leads

•

Check integrity of power cable connectors

•

Check power input voltage (6 to 36 VDC)

•

Check current restrictions imposed by power source

(minimum available should be > 1.0 A)

No data from

3D

•

Check receiver power status to ensure the receiver is
powered (an ammeter can be used for this)

•

Verify desired messages are activated (using SI-TEX
Toolkit or $JSHOW in any terminal program)

•

Ensure the baud rate of the

3D

matches that of the receiving

device

•

Check integrity and connectivity of power and data cable
connections

Random data from

3D

•

Verify the RTCM or binary messages are not being output
accidentally (send a $JSHOW command)

•

Ensure the baud rate of the

3D

matches that of the remote

device

•

Potentially, the volume of data requested to be output by the

3D

could be higher than the current baud rate supports (try

using 19200 as the baud rate for all devices or reduce the
amount of data being output)

No GPS lock

•

Verify the

3D

has a clear view of the sky

•

Verify the lock status of GPS satellites (this can be done with
SI-TEX Toolkit)

Advertising