Table 1: detector led modes – Silent Call 1008-4 User Manual

Page 16

Advertising
background image

16

Table 1: Detector LED Modes

Green LED

Red LED

Piezoelectric Horn

Power-up

Blinks every 5
seconds

Blinks every 5
seconds

Off

Normal (standby) Blinks every 10

seconds

Off

Off

Out of sensitivity

Off

Blinks every 5
sec

Off

Smoke Alarm

Off

Blinks every 1
sec

Temporal Pattern

Low Battery

Off

Blinks every 45
sec

Chirp every 45 sec after
LED blinks for 7 days

During initial power-up, the red and green LEDs will blink
synchronously once every 5 seconds. It will take approximately 20
seconds for the detector to finish the power-up cycle (see Table 1).

After power-up has been completed and the detector is functioning
normally within its listed sensitivity range, the green LED blinks once
every 10 seconds. If the detector is in need of maintenance because
its sensitivity has shifted outside the listed limits, the red LED blinks

Advertising