C

ountertop

W

arming

and

d

isplay

O

peratOr

s

M

anual

2

U

npacking

the

e

qUipment

and

i

nitial

S

etUp

When no longer needed, dispose of all packaging and materials in an

environmentally responsible manner. Have the unit installed only by qualified

service personnel. This unit must be installed in accordance with any local

and national plumbing codes. See back of this document for kit contents.
Tools and Supplies Required:

„

#2 Flat Blade Screwdriver

„

#2 Phillips Screwdriver

„

Wire Stripper

„

Pipe Wrench or Pliers

„

Silicone, High Temperature, NSF Listed

„

Utility Knife

Installation of Auto Drain Model Kits:

1. Turn power switch to the “OFF” position and unplug from power source.
2. Remove all water from the wells.
3. Remove the stub pipe (B) by unscrewing it from the well bottom (A). See

Figure 1.

A

B

Figure 1. Removal of stub Pipe.
4. Place a small bead of high temperature NSF listed silicone on the

threads on fitting (B) of the valve assembly (C). See Figure 2.

A

B

C

Figure 2. Manifold Assembly and Well Fitting.

S

afety

p

recaUtionS

To ensure safe operation, read the following statements and

understand their meaning. Please read carefully.

WARNING

Warning is used to indicate the presence of a hazard that can cause

severe personal injury, death, or substantial property damage if the

warning is ignored.

CAUTION

Caution is used to indicate the presence of a hazard that will or can

cause minor personal injury or property damage if the caution is

ignored.

nOTE

Note is used to notify people of installation, operation, or

maintenance information that is important but not hazard-related.

For Your safety!

These precautions should be followed at all times. Failure to follow

these precautions could result in injury to yourself and others.

To reduce risk of injury or damage to the equipment:

„

Read and understand all installation and operation instructions before

installing or operating equipment.

„

This equipment must be installed by a licensed electrician or certified

service personnel.

„

Prior to installation the unit must be unplugged from its power source.

„

Use only grounded electrical outlets matching the nameplate rated

voltage.

„

Do not spray controls or outside of equipment with liquids or cleaning

agents.

„

Keep equipment and power cord away from open flames, electric

burners or excessive heat.

f

Unction

and

p

UrpoSe

Drain kits 36672auto, 36673auto, 36674auto and 36674man are designed to

be installed on Vollrath Hot/Cold Well models only. Check vollrathco.com for

product list.
This product is intended to drain the water from a well.
This equipment is not intended for household, industrial or laboratory use.

o

perational

S

tatement

The Auto Drain units operate by emptying the reservoir after the mode switch

on the unit it is moved to the refrigeration mode. When the well control switch

is in the refrigerate mode the valve stays in the “open” position. When the

well control switch is in the center or heat position the valve remains in the

“closed” position.
The Manual Drain units require an operator to manually install a drain plug in

order for the well to hold water or to remove the drain plug to allow the water

to drain.