Vollrath Cayenne Gas Hot Plates User Manual

Page 4

Advertising
background image

4

GAS HOT PLATE


Gas connection: The appliance comes fitted with a ¾” N.P.T male adapter for

connection to the pressure regulator.


Gas piping: Gas Piping shall be of such size and so installed as to provide a supply of

gas sufficient to meet the full gas input of the appliance. If the appliance is to be
connected to existing piping, it shall be checked to determine if it has adequate
capacity. Joint compound (pipe dope) shall be used sparingly and only on the male
threads of the pipe joints. Such compounds must be resistant to the action of L.P
gases.


CAUTION:
Any loose dirt or metal particles, which are allowed to enter the gas lines on

this appliance, will damage the valve and affect its operation. When installing this
appliance, all pipe and fittings must be free from any internal contaminates. It is
recommended that a “drip leg” be installed inline before the regulator.


Manual shut off valve: A manual shut off valve should be installed upstream from the

manifold and within 4 ft (1.2m) of the appliance and in a position where it can be
reached in the event of an emergency.


Checking for gas leaks: A soapy water solution is recommended for locating gas

leakage. Matches, candle flame or other sources of ignition shall not be used for this
purpose. Check entire piping system for leaks.


Exhaust canopy: Cooking burnerss inherently create a good deal of heat and smoke

and should be installed under an efficient exhaust hood with flame proof filters. A
vertical distance of not less than 4 ft (1.2m) shall be provided between the top of the
appliance and filters or any other combustible material.


Lighting the pilot: The units are equipped with standing pilots, and should be lit

immediately after the gas is supplied to the appliance.

1. Turn off the main valve to the unit and wait 5 minutes to clear gas.
2. Turn off all knobs and pilot valves.
3. Turn on main valve and light all pilots.
4. The pilot burner must be lit at the end of the tube. Hold an ignition source through

the opening in the front panel at the pilot tube. When the flame is established
remove ignition source.

Note: Smoke appearing on initial use of the appliance is normal. This is as a result of
the rust

preventing coating burning off. Allow the unit to ‘burn in’ for at least 30 minutes

before the first use.

IMPORTANT: If you smell gas close the shut off valve, open windows, ventilate and
evacuate the area immediately. Do not touch electrical switches or plugs. Extinguish
any open flames. Immediately call your gas supplier.

Advertising