SPECIFICATIONS:
Power Source:

24V DC, 2A. PS-2420UL (x2)

(1 for audio-only system,

2 for audio/video system)

Current
Consumption:

Video(Max) 0.62A, Audio(Max) 0.65A

Door
Release Contact:

24V AC/DC, 500mA

Mounting:

Desk, wall, or 19: EIA rack with
supplied brackets

Wiring:

RJ45 plugs for CAT-5e homerun wire
runs from each master and door/sub
2 Conductor wire from PS-2420UL to
power input terminals

CO Line Port:

RJ11 for Viking K-1900-5
programmable auto-dialer

Housing: Metal

Color: Black

Operating Temp: 32 – 104

°

F (0 ~ 40

°

C)

Dimensions:

3-7/16" x 1' 6-7/8" x 1' 1-3/16"

(HxWxD)

(88 x 480 x 335 mm)

Weight: 10.35

lbs

(4,700g)

FEATURE CALL-OUTS:

AX-084C Spec Sheet
0209 Pg. 2

FEATURE CALL-OUT DEFINITIONS:

[1] Power switch
[2] Door station ports
[3] Master station ports
[4] Add-on exchange unit port
[5] CO line port (Viking K-1900-5 auto dialer required)
[6] Setting/log port
[7] Video output ports
[8] Video output trigger ports
[9] Door release relay ports (L1 corresponds to door

station D1, L2 to door station D2, etc.)

[10] Power supply ports
[11] Power/Communications error display LE

D1 D3 D5 D7
D2 D4 D6 D8

DOOR RELEASE RELAY
L1 L2 L3 L4 L5 L6 L7 L8

M1 M3
M2 M4

VCH1 VCH2

X1 OUT X2
AX-320C

CO

+ - + -

D-PS V-PS

RS-232C

POWER

VIDEO OUT
V1 V2

AIPHONE AX-084C

[9]

[2]

[3]

[4]

[8]

[7]

[6]

[5]

[10]

[11]

[1]

PACKAGE CONTENTS:

[1]

[2]

[3]

[4]

[5]

[6]

[1] AX-084C Exchange Unit
[2] Mounting screws
[3] Rack/Wall mounting brackets
[4] Installation CD, including set-
up software program and
instruction manual
[5] Mounting screws (for 19-inch
rack mounting)
[6] USB to serial programming
cable with driver