WATER SYSTEM PIPING

FIGURE 8

Typical Water Piping Installation

FIGURE 9

Typical Tempering

Valve Installation

Tempered Water

to fixtures

Cold

Water

Inlet

Tempering Valve

(set to 120°F

or lower)

Piping Installation

Piping, fittings, and valves should be installed according to

the installation drawing (Figure 8). If the indoor installation

area is subject to freezing temperatures, the water piping

must be protected by insulation.
Water supply pressure should not exceed 80 psi. If this

occurs a pressure limiting valve with a bypass may need

to be installed in the cold water inlet line. This should

be placed on the supply to the entire house in order to

maintain equal hot and cold water pressures.
IMPORTANT: Heat cannot be applied to the water fittings

on the heater as they may contain nonmetallic parts. If

solder connections are used, solder the pipe to the adapter

before attaching the adapter to the hot and cold water

fittings.
IMPORTANT: Always use a good grade of joint compound

and be certain that all fittings are drawn up tight.
1. Install the water piping and fittings as shown in Figure

8. Connect the cold water supply (3/4” NPT) to the

fitting marked “C”. Connect the hot water supply (3/4”

NPT) to the fitting marked “H”. IMPORTANT: Some

models may contain energy saving heat traps to

prevent the circulation of hot water within the pipes. Do

not remove the inserts within the heat traps.

2. The installation of unions in both the hot and cold

water supply lines is recommended for ease of

removing the water heater for service or replacement.

3. The manufacturer of this water heater recommends

installing a tempering valve or an anti-scald device

in the domestic hot water line as shown in Figure 9.

These valves reduce the point of use temperature of

the water by mixing cold and hot water and are readily

available for use. Point of use devices for reducing

scald hazards that attach to faucets and shower heads

are also available from plumbing supply houses.

Contact a licensed plumber or the local plumbing

authority.

4. If installing the water heater in a closed water system,

install an expansion tank in the cold water line as

specified under “Closed System/Thermal Expansion”.

5. Install a shut-off valve in the cold water inlet line. It

should be located close to the water heater and be

easily accessible. Know the location of this valve and

how to shut off the water to the heater.

6. A temperature and pressure relief valve must be

installed in the opening marked “Temperature and

Pressure (T & P) Relief Valve” on the water heater.

Add a discharge line to the opening of the T & P relief

valve. Follow the instructions under Temperature and

Pressure Relief Valve”.

Please note the following:

The system should be installed only with piping that is
suitable for potable (drinkable) water such as copper,
CPVC, or polybutylene. This water heater must not be
installed using iron piping or PVC water piping.

Use only pumps, valves, or fittings that are compatible
with potable water.

Use only full flow ball or gate valves. The use of valves
that may cause excessive restriction to water flow is
not recommended.

Use only 95/5 tin-antimony or other equivalent solder.
Any lead based solder must not be used.

Piping that has been treated with chromates, boiler
seal, or other chemicals must not be used.

Chemicals that may contaminate the potable water
supply must not be added to the piping system.