Symptom-to-FRU index

This section contains following information:

“Numeric error codes” on page 32

“Undetermined problems” on page 33

The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most
likely cause is listed first, in boldface type.

Note: Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or
action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the
computer. Do not replace a nondefective FRU.

This index can also help you determine, during regular servicing, what FRUs are likely to need to be
replaced next.

A numeric error is displayed for each error detected in POST or system operation. In the displays, n can
be any number.

If no numeric code is displayed, check the narrative descriptions of symptoms.

Numeric error codes

Table 1. Numeric error codes

Symptom or error

FRU or action, in sequence

0177
Bad SVP data, stop POST task.

Checksum of the supervisor password in the EEPROM is
not correct. The system board should be replaced. Have
the computer serviced.

0183
Bad CRC of Security Settings in EFI Variable. Enter
ThinkPad Setup.

Checksum of the Security settings in the EFI Variable
is not correct. Enter ThinkPad Setup to check Security
settings, Press F10 and then press Enter to restart the
system. If you still have a problem, have the computer
serviced.

0187
EAIA data access error.

The access to EEPROM is failed. Have the computer
serviced.

0188
Invalid RFID Serialization Information Area.

The EEPROM checksum is not correct (block # 0 and
1). The system board should be replaced, and the box
serial number needs to be reinstalled. Have the computer
serviced.

0189
Invalid RFID configuration information area.

The EEPROM checksum is not correct (block # 4 and
5). The system board should be replaced, and the UUID
needs to be reinstalled. Have the computer serviced.

0190
Critical low-battery error.

The computer turned off, because the battery is low.
Connect the ac adapter to the computer and charge the
battery.