Step 3. select the number of ds0s/port, Configuration for dte port – ADTRAN TSU 600 User Manual
Page 99
Advertising

Chapter 4. Example Operations
61200.076L2-1
TSU 600 User Manual
87
Step 2. Configure DTE Port (1.1 - Nx56/64) (From Option
Module)
Table 4-B provides configuration information for DTE
ports.
Table 4-B
Configuration for DTE Port
MENU ITEM
SELECTION USED
SELECTIONS AVAILABLE
1)INTERFACE
V.35
V.35, RS530
2)RATE 56/64
56K
56K, 64K
3)TX CLK CNTRL
INTERNAL
INTERNAL, INTERNAL & INVERTED,
EXTERNAL
4)DATA
NORM
NORMAL, INVERT
5)CTS
FORCED ON
NORMAL, FORCE ON
6)DCD
FORCED ON
NORMAL, FORCE ON
7)DSR
FORCED ON
NORMAL, FORCE ON
8)"O" INHIB
ON
ON, OFF
Step 3. Select the number of DS0s/Port:_____12___
The number of DS0s/Port is based on the Data Rate
Table in the appendix, Configure DTE Port:
Advertising