R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R

Y

B

G

E

W2

L

X

B

RHEEM

/RUUDLOW

VOLTAGE TERM

INAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO RHEEM/RUUD

HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [HEATING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

SYSTEM MONITOR LED

24 VAC, COMMON

R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R

Y

O

G

W2

L

C

PAYNE LOW

VOLTAGE TERM

INAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO PAYNE

RELIANT AND ENDURA MODEL HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [COOLING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

SYSTEM MONITOR LED

24 VAC, COMMON

3RD. STAGE HEATING CIRCUIT [CAPPED]

NOTE 1: W3 TERMINAL ON

PAYNE PCB CAPPED

E

W3