Aprilaire 8336 User Manual

Page 15

Advertising
background image

15

R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R-VR

Y1

O

F

E

W1

X

LENNOX LOW

VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO LENNOX

HP21 WITH CB21 PCB HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [COOLING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

24 VAC, COMMON

L

Y2

R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R-VR

M

R

F

E

Y

X

LENNOX LOW

VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO LENNOX

HP22 WITH CB19 PCB HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [HEATING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

SYSTEM MONITOR LED

24 VAC, COMMON

2ND. STAGE COOLING CIRCUIT

L

Y2