Installing an X330WAN Module into an Avaya P330 Switch

Avaya X330WAN User’s Guide

11

5

Follow the post-installation checks, as described in "Power On Self Test" on
page 11.

Power On Self Test

When you power up the Avaya P330 switch with a X330WAN module inserted,
both the P330 switch and the X330WAN perform a self test. This test takes about 40
seconds to complete, and includes:
•

Checksum tests of boot and system areas of Flash memory

•

System memory tests

•

MAC address verification test

•

System timer test

•

CAM (Contents Addressable Memory) tests

•

Console Port tests

•

Internal packet forwarding tests

•

Switch and expansion module ASIC (Application Specific Integrated Circuit)
tests

•

Switch and expansion module ASIC memory tests

•

Expansion module interface tests

•

Expansion module packet forwarding tests

After you insert an X330WAN access router module into a powered P330 switch,
causing a reset, or after a power cycle of the host P330 switch, the X330W-2DS1
startup sequence is as follows:
1

Initially all LEDs light for 15 seconds and then switch off.

2

The ALM LEDs light for 15 seconds and then switch off.

3

The TST LEDs lights for 15 seconds and then switch off.

4

At this point, the ALM LED lights again if there is no line signal detected on the
E1/T1 ports. If a signal is detected on the line, the SIG LEDs light and the ALM
LEDs switch off.

The X330W-2USP startup sequence is as follows:
1

All LEDs light for 15 seconds, then switch off.

2

All LEDs remain off for 15 seconds.

3

The OPR LED lights and remains on.

Note:

LED Number 51 on the Avaya P330 switch should be ON during the self-test

procedure.

The X330WAN module must be inserted completely for the P330 switch to
successfully reset.