3-2

3.1

Removal Procedures

3

3

Removing Fusing Unit EF-102

This section describes the procedures to remove EF-102 and the feed guide parts for envelopes.

When using paper other than envelopes, follow the procedure below to replace the fusing unit and remove
the parts installed in the tray.

3.1

Removal Procedures

3.1.1

Removing EF-102 from the Main Body

1

Turn off the machine's sub and main power switches, and then unplug the power cord from the outlet.

% Be sure to turn off the sub power switch first.

2

Open the front door, and then the left side door of the main body.

3

While releasing the ADU drawer lock by pressing it to the
left (Arrow [1]) with a screwdriver inserted into the gap un-
der the lever [M4], turn the lever [M4] down to the right (Ar-
row [2]).

% When the machine is not powered, the lever [M4] can-

not be turned unless the lock is released.

4

Hold the lever [M4] and pull out the ADU drawer.

5

Hold the lever [M8] and open the reversing paper exit unit.

6

Rotate the lock screw (purple) to the direction of arrow to
release the lock.