Electrical connection for the uk, Appliances with 2 wires – AEG DUNSTABZUGSHAUBE 825 D User Manual

Page 6

Advertising
background image

22

Electrical connection for the UK

Appliances with 2 wires

The appliance must be connected to fixed wiring with a double

pole switched fused spur outlet with or without pilot lamp.

We strongly recommend the appliance to be connected only by a

qualified electrician who is a member of the NICEIC who will com-

ply with the IEE and any local regulations.

NOTE:

The terminology “DOUBLE POLE” means that both the live and the

neutral supplies are switched and disconnected at the same time.

The terminations labelled SUPPLY are for the connection for the

internal house wiring and the terminations labelled LOAD are for

the appliance.

IMPORTANT

The wires of the mains lead supplied with this appliance are

coloured in accordance with the following code:

Blue-Neutral

Brown-Live

As the colours of the flexible cord of this appliance may not

correspond with the coloured markings identifying the ter-

minals in the plug, proceed as follows: The wire which is col-

oured brown must be connected to the terminal which is

marked with the letter L or coloured red.

The wire which is coloured blue must be connected to the

terminal which is marked with the letter N or coloured black.

N

LOAD

L

SUPPLY

L

LOAD

N

SUPPLY

DP 13A, 250V

BLUE

(NEUTRAL)

BROWN

(LIVE)

FUSE

ON

Advertising
This manual is related to the following products: