Replacement of the connection cable, Building in, Possibilities for insertion – AEG HG755520UM User Manual

Page 11

Advertising
background image

The replacement of electric cable must be carried out exclusively by the service force centre

or by personnel with similar competencies, in accordance with the current regulations.

Replacement of the connection cable

To replace the connection cable use only H05V2V2-F T90 or equivalent type. Make sure that

the cable section is applicable to the voltage and the working temperature. The yellow/

green earth wire must be approximately 2 cm longer than the brown (or black) phase wire.

Building In

min. 55 mm

min. 650 mm

560 mm

min. 450 mm

30 mm

480 mm

min. 600 mm

10 mm

86 mm

86 mm

A

3 mm

A

B

A) supplied seal
B) supplied brackets

Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must be easy to remove and let an easy access in case a

technical assistance intervention is necessary.

Installation