Adjustment of minimum level

To adjust the minimum level of the burners:
1.

Light the burner.

2.

Turn the knob on the minimum position.

3.

Remove the knob.

4.

With a thin screwdriver, adjust the by-pass screw position.

1

1

The by-pass screw

– If you change from natural gas 20 mbar to liquid gas, fully tighten the by-pass

screw in.

– If you change from liquid gas to natural gas 20 mbar, undo the by-pass screw ap-

proximately 1/4 of a turn (1/2 of a turn for Triple Crown burner).

WARNING!

Make sure the flame does not go out when you quickly turn the knob from the maximum

position to the minimum position.

Electrical connection

• Any electrical work required to install this hob should be carried out by a qualified elec-

trician or competent person, in accordance with the current regulations.

• THIS HOB MUST BE EARTHED.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug after installation.
• Do not pull the mains cable to disconnect the appliance. Always pull the mains plug.
• The appliance must not be connected with an extension cable, an adapter or a multiple

connection (risk of fire). Check that the ground connection is in conformity with the

standard and regulations force.

• The power cable must be placed in such a way that it does not touch any hot part.
• Connect the appliance to the mains with a device that lets to disconnect the appliance

from the mains at all poles with a contact opening width of minimum 3 mm, eg. auto-

matic line protecting cut-out, earth leakage trips or fuse.

• None of a parts of the connection cable can not get a temperature 90°C.

Electrical Requirements

Any permanent electrical installation must comply with the latest I.E.E. Regulations and lo-

cal Electricity Board regulations. For your own safety this should be undertaken by a quali-

Installation