8.4 Adjustment of minimum
level

To adjust the minimum level of the burn-
ers:

1.

Light the burner.

2.

Turn the knob on the minimum posi-
tion.

3.

Remove the knob.

4.

With a thin screwdriver, adjust the
by-pass screw position.

A

A)

The by-pass screw

• If you change from natural gas G20 20

mbar to liquid gas, fully tighten the
by-pass screw in.

• If you change from liquid gas to natu-

ral gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2
of a turn for Triple Crown burner).

WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.

8.5 Electrical connection

• Do not pull the mains cable to discon-

nect the appliance. Always pull the
mains plug.

• The appliance must not be connected

with an extension cable, an adapter or
a multiple socket. There is a risk of fire.

• Do not let the power cable to heat up

to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the cabi-
net, in order to avoid any contact with
the equipment beneath the cooktop.

• Make sure that there is access to the

mains plug after the installation.

Electrical Requirements

Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations.
For your own safety the installation must
be done by a qualified electrician (e.g.
your local Electricity Board, or a contrac-
tor who is on the roll of the National In-
spection Council for Electrical Installa-
tion Contracting [NICEIC]).

The manufacturer refuses to be
held responsible, if these safe-
ty measures are not abided by.

Supply connections:
This hob has to be connected to 230 —
240 V ( 50 Hz) electricity supply.

The hob has a terminal block which is
marked as follows:
L — Live terminal
N — Neutral terminal

or E — Earth terminal

Before carrying out the connection,
make sure:

1.

The limiter valve and the electrical
system can take the appliance load
(see the rating plate)

2.

The supply system is equipped with
an efficient earth connection in com-
pliance with the current standards
and regulations

3.

The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.

The appliance is supplied with a 3 core
flexible powercable with a 3 amp plug. If
it is necessary to change the fuse, use a
3 amp ASTA-approved (BS 1362) fuse.